4 - 3
4.2.1 Basic system setting
The basic system setting contents are shown below.
Default
No. Item Setting range
Initial
value
Units
Remarks
1
Operation cycle
setting
0: 0.8ms
1: 1.7ms
2: 3.5ms
3: 7.1ms
4: 14.2ms
5: Automatic setting
5 ms
• Set the motion operation cycle.
2
Operation
setting for
STOP → RUN
0: Turns on M2000 when the switch is changed from STOP to
RUN.
1: Turns on M2000 when the switch is changed from STOP to
RUN and the setting register (D704) is set to "1".
0 –
• Set such condition as to turn on
the PLC READY flag (M2000).
3
Emergency
stop input
setting
0: No setting
1: X (PX) (0 to 1FFF)
2: M (0 to 1FFF)
0 –
• Set the bit device for
emergency stop.
• Bit device OFF → While
emergency stop input is ON
• Bit device ON → While
emergency stop input is OFF
4
Latch range
setting
Sets the range (latch (1)) that can be cleared using latch clear
key and the range (latch (2)) that cannot be cleared using latch
clear key.
– –
• Set the latch range for devices
(M, B, F, D, W) respectively.